 
       
      | Bieżący numer
			Archiwum
		
				Filmy
				Artykuły w druku
				O czasopiśmie
				Suplementy
					Rada naukowa
				Recenzenci
				Bazy indeksacyjne
		
			
					Prenumerata
				Kontakt
				Zasady publikacji prac
	             Opłaty publikacyjne
     			Standardy etyczne i procedury Panel Redakcyjny Zgłaszanie i recenzowanie prac online | 
		3/2007
	 vol. 109 streszczenie artykułu: Artykuł oryginalny Operacja zaćmy z mikrocięcia rogówki z jednoczesnym wszczepem soczewki Acri.Smart 48S
	
	             Wojciech  Lubiński
	         1 , 
	             Karolina  Podborączyńska-Jodko
	         1 , 
	             Krzysztof  Barnyk
	         1 , 
	             Danuta  Karczewicz
	         1 
 Klinika Oczna 2007, 109 (3): 267-271 Data publikacji online: 2007/09/27 
	Pełna treść artykułu
	
	
	
	Pobierz cytowanie
 ENWEndNote BIBJabRef, Mendeley RISPapers, Reference Manager, RefWorks, Zotero AMA APA Chicago Harvard MLA Vancouver Purpose To evaluate visual and refractive outcome and complications after microincision cataract surgery (MICS) with implantation of an Acri.Smart 48S intraocular lens (IOL). Material and methods This study comprised 22 eyes of 11 patients having bilateral microincision cataract surgery. MICS was performed through a 1.4 mm clear corneal incision using the MacKool System and low ultrasound power. The IOL was implanted through a 1.7 or smaller clear corneal incision with a Acri.Smart Glide System. The final size of the clear corneal incision, postoperative uncorrected and best corrected distance visual acuity, best corrected near visual acuity (Snellen, Jaeger Table), astigmatism, pseudoaccommodation possibility of Acri.Smart 48S IOL, complications and patient satisfaction were analyzed. The follow up was 1 month. Results The Acri.Smart 48S lens was implanted through mean incision of 1.56 ± 0.07 mm. One month after surgery the mean uncorrected distance visual acuity (UCVA) and the best corrected visual acuity (BCVA) significantly improved (UCVA: preoperatively – 0.49 ± 0.33; postoperatively – 0.97 ± 0.11; p <0.001; BCVA: preoperatively 0.68 ± 0.3; postoperatively – 1.0; p<0.001) as well as BCVA for near (BCVA: preoperatively – 5.27 ± 3.30; postoperatively – 2.91 ± 1.48; p=0.002). One month after surgery, there was not significant increase of astigmatism and the pseudoaccommodative ability of Acri.Smart 48S was not observed. There were no serious intraoperative and postoperative complications. All the patients were highly satisfied with the quality of the vision. Conclusions Our preliminary results show that MICS with Acri.Smart 48S lens implantation is safe and effective procedure. This conclusion has to be confirmed by studies with longer follow up period and larger series of patients. słowa kluczowe: chirurgia zaćmy z mikrocięcia, wszczepienie soczewek AcriSmart 48S |