 
       
      | Bieżący numer
			Archiwum
		
				Filmy
				Artykuły w druku
				O czasopiśmie
				Suplementy
					Rada naukowa
				Recenzenci
				Bazy indeksacyjne
		
			
					Prenumerata
				Kontakt
				Zasady publikacji prac
	             Opłaty publikacyjne
     			Standardy etyczne i procedury Panel Redakcyjny Zgłaszanie i recenzowanie prac online | 
		3/2007
	 vol. 109 streszczenie artykułu: Artykuł oryginalny Funkcja wzroku i powikłania po obuocznej operacji zaćmy i wszczepie refrakcyjnych soczewek wieloogniskowych
	
	             Wojciech  Lubiński
	         1 , 
	             Jolanta  Gronkowska
	         1 , 
	             Krzysztof  Barnyk
	         1 , 
	             Zbigniew  Szych
	         1 , 
	             Danuta  Karczewicz
	         1 
 Klinika Oczna 2007, 109 (3): 261-266 Data publikacji online: 2007/09/27 
	Pełna treść artykułu
	
	
	
	Pobierz cytowanie
 ENWEndNote BIBJabRef, Mendeley RISPapers, Reference Manager, RefWorks, Zotero AMA APA Chicago Harvard MLA Vancouver Purpose To evaluate the visual function and complications after cataract surgery with bilateral Array SA 40N multifocal intraocular lens (IOL) implantation. Material and methods This prospective study comprised 40 eyes of selected 20 patients undergoing cataract surgery with bilateral implantation of Array SA 40N (AMO). multifocal IOL. Three months after bilateral surgery distance and near visual acuity, contrast sensitivity, complications and adverse effects were evaluated. Patients’ satisfaction was assessed using a subjective TyPE Questionnaire. Results Thirty-five eyes (35/40 – 87.5%) achieved the uncorrected distance visual acuity 20/40 and the uncorrected near visual acuity of J5 or better. Eighty-two and a half percent of the operated eyes achieved UCDVA 20/20 and J4 or better. Contrast sensitivity for distance and near measured binocularly were within normal limits, although for higher spatial frequency, contrast sensitivity values for near were slightly above the lower limit of normal range. Intraoperative and postoperative complications were few and only in one eye, further surgical intervention was necessary (IOL recentration). Three patients (3/20 – 15%) reported moderate glare and halo. Overall visual satisfaction measured with TyPE Questionnaire was very high (8.7/10). Conclusions Bilateral multifocal IOL implantation was effective and safe in selected cataract patients, providing very good uncorrected distance and near visual acuity. Slightly reduced contrast sensitivity and increased perception of glare/halo were an acceptable compromise for near, as well as distance vision improvement. słowa kluczowe: operacja zaćmy, wszczep soczewki wieloogniskowej, funkcja wzroku, powikłania |