Abstract
Ophthalmological tests value in detection of the optic neuropathy associated with pituitary tumours
- Katedra i Klinika Okulistyki Pomorskiej Akademii Medycznej w Szczecinie
- Wojewódzka Poradnia Endokrynologiczna w Szczecinie
- Klinika Endokrynologii, Nadciśnienia Tętniczego i Chorób Przemiany Materii Pomorskiej Akademii Medycznej w Szczecinie
- Zakład Higieny i Epidemiologii Pomorskiej Akademii Medycznej w Szczecinie
Introduction
To evaluate the value of ophthalmological tests in detection of the optic neuropathy associated with pituitary tumours.
Material and methods
38 patients with pituitary tumours in 21–73 years old, were examined. Routine ophthalmological examination, kinetic and static perimetry (screening test, „white-on-white” and „blue-on-yellow”) and PVEP were performed.
Results
In patients with recurrent tumours (group II) more changes was observed in routine ophthalmological examination, perimetry and PVEP compared to patients with early detected pituitary tumours (group I). No patient of group I present changes in routine ophthalmological examination, but they had visual field defects and/or abnormal PVEP. In group I in Ps B-Y more visual field defects was detected than in kinetic perimetry (p<0.025). In the same group hemifield PVEP was more often abnormal than full-field PVEP (p<0.01). In group II similar differences were not observed.
Conclusions
In patients with pituitary tumours the most useful test in the optic neuropathy diagnosis are „blue-onyellow” static perimetry and hemifield PVEP.
Keywords
pituitary tumours, perimetry, visual evoked potentials