Klinika Oczna

Abstract

3/2007 vol. 109
Original paper

Phacoemulsification of subluxated lens with capsular tension ring implantation

Klinika Oczna 2007, 109 (3): 280-282
Online publish date: 2007/09/27
View full text

Purpose

To evaluate long term results of phacoemulsification with PC IOL and capsular tension ring (CTR) implantation in lens subluxation.

Material and methods

The study comprised of 134 patients – 146 eyes with subluxated lens. In all cases phacoemulsification with PC IOL and CTR implantation was performed.

Results

No intaroperative complications has occured. Postoperative complications included: inflammation in the anterior chamber in 3 eyes (2.1%), retinal detachment in 2 eyes (1.4%). In all cases there was no PC IOL decentration.

Conclusions

1. CTR facilitates phacoemulsification with PC IOL implantation in lens subluxation. 2. Phacoemulsification of subluxated lens with PC IOL and CTR implantation seems to be safe and effective

Share
without publication fees
without publication fees