Abstract
4/2005
vol. 107
Case report
Broken part of IOL haptic as a cause of bullous keratopathy. Case report
- Z Kliniki Okulistyki i Rehabilitacji Wzrokowej Uniwersytetu Medycznego w Łodzi
Klinika Oczna 2005, 107 (4): 687-689
Online publish date: 2005/12/18
Presentation of the case of the patient in whom1 year after penetrating keratoplasty a broken, free moving haptic part of the IOL within anterior chamber was found. In accordance to increases of pain and high likelihood of donor corneal flap damage decision about surgical removal of free haptic was undertaken. Finding of the broken part of IOL throw light on the cause of bullous keratopathy in this case.
Keywords
bullous keratopathy, IOL, perforating keratoplasty