twitter
en POLSKI
eISSN: 2719-3209
ISSN: 0023-2157
Klinika Oczna / Acta Ophthalmologica Polonica
Current issue Archive Videos Articles in press About the journal Supplements Editorial board Reviewers Abstracting and indexing Subscription Contact Instructions for authors Ethical standards and procedures
Editorial System
Submit your Manuscript
SCImago Journal & Country Rank
4/2011
vol. 113
 
Share:
Share:
abstract:
Original paper

Evaluation of surgically induced astigmatism after coaxial phacoemulsification through 1.8 mm microincision and standard phacoemulsification through 2.75 mm incision

Michal Wilczynski
1
,
Ewa Supady
1
,
Piotr Loba
1
,
Aleksandra Synder
1
,
Dorota Palenga-Pydyn
1
,
Wojciech Omulecki
1

  1. 1st chair and Department of Ophthalmology, Medical University of Lodz
Klinika Oczna 2011, 113 (4): 314-320
Online publish date: 2011/12/04
View full text Get citation
 
Introduction
Improvements in technology connected with cataract surgery have made it possible to decrease significantly the size of corneal incision created during phacoemulsification. Recently, coaxial phacoemulsification through a 1.8 mm microincision (C-MICS) has been introduced. This technique is perceived as the next step in development of phacoemulsification. Purpose: To compare surgically induced astigmatism (SIA) after coaxial 1.8 mm microincision cataract surgery (C-MICS) and standard phacoemulsification through 2.75 mm incision, calculated with three mathematical methods.

Material and methods
A consecutive, prospective series of 55 eyes of 55 patients who underwent uneventful C-MICS with foldable IOL implantation using 1.8 mm temporal clear corneal incision were included in group 1. Reference group (group 2) included 55 eyes of 55 patients who underwent uneventful phacoemulsification through 2.75 mm temporal clear corneal incision with a foldable IOL implantation. SIA was calculated using three methods.

Results
All patients had uneventful surgery and were examined before the surgery and one month postoperatively. There was a significant postoperative increase in corrected distance visual acuity in both groups (p<0.01), and the visual outcomes in both groups were similar (p>0.05). In vector analysis, mean SIA was 0.42 ± 0.30 in group 1 and 0.77 ± 0.55 in group 2. In vector decomposition, the mean SIA (C90) in group 1 was 0.24 ± 0.29 and 0.49 ± 0.54 in group 2 (p<0.05). In Naeser’s polar values method, ΔKP-0 was -0.06 ± 0.43 in group 1 and -0.21 ± 0.84 in group 2 (p>0.05).

Conclusions
1.8 mm coaxial MICS induces a significantly smaller value of SIA than standard 2.75 mm phacoemulsification.