abstract:
Original paper

An implantation of multifocal lenses LS-313 MF30, Mplus and MplusX models, during and after posterior vitrectomy in patients treated for various diseases of the retina

Adam Cywiński
1
,
Anna Piwońska-Lobermajer
1
,
Sandra Penter
1

1.
Śląski Ośrodek Leczenia Chorób Oczu
Online publish date: 2017/11/29
View full text Get citation
 
PlumX metrics:
Purpose
A retrospective analysis of visual function and postoperative complaints in patients after posterior vitrectomy and multifocal Mplus or MplusX intraocular lens implantation.

Material and methods
14 patients (14 eyes) were enrolled in the study. All patients underwent posterior vitrectomy due to underlying retinal pathologies. A combined procedure of phacovitrectomy was performed in some patients, whereas others underwent a separate cataract extraction as a second stage of treatment. The Mplus or MplusX intraocular lenses were implanted in all cases and the postoperative visual function and patient complaints were analysed.

Results
Multifocal lens explantation was not necessary in any case. Good uncorrected distance and near visual acuity was achieved in most cases. When implanted prior to vitrectomy, the intraocular lenses did not limit the view into the posterior segment, so precise manipulations within the macula and peripheral retina were feasible. The right choice between Mplus and MplusX minimises the rate of postoperative complaints.

Conclusions
The multifocal Mplus and MplusX intraocular lenses offer a good alternative for patients who need posterior vitrectomy and still want to achieve good uncorrected distance and near visual acuity.

keywords:

multifocal intraocular lens, posterior vitrectomy, Mplus, combined procedures, macular hole, retinal detachment, epiretinal membrane